SADAR® Technology

Real-Time Subsurface Activity Detection

PRODUCT DETAILS

SADAR® is an event-driven, seismic-acoustic monitoring technology solution that classifies and locates subsurface events of interest, automatically and in real-time.

THE SADAR® ADVANTAGE

Leveraging compact, phased array processing, SADAR® delivers greater range and accuracy via a reduced seismic data acquisition network. By including spatial processing into the analytic sequence, SADAR® is able to detect, associate, locate, and identify events of interest in the presence of elevated noise and clutter.

Features

  • Persistent
    • Always on, always listening, always processing
  • Real-Time
    • Timely information is actionable information resulting in informed decision making
  • Highly Sensitive
    • Greater Range
  • Compact, phased arrays
    • Spatial analytics enhance results and disassociate unwanted noise and clutter
    • Improved locations with reduced uncertainty
  • Reduced Surface Footprint
    • Environmental and land owner upside
    • Lower risk to lifecycle and maintenance costs
  • User Interface Interactive Map Displays
    • Array(s) location
    • State-of-health status of individual SADAR® arrays
    • Detection, classification, and localization alerts

GEORES s8 (SERVER)

19in Rack-Mount Chassis
4U
SADAR-E Array Line Support per Chassis
8
SADAR-E Arrays per Line
7
Operating Temperature
-20°C to 60°C
Input Voltage Power
100-260 VAC, 10W
Array Power Supplied via 450-05290-xx
Passthrough
Dimensions
19 in (W) x 13.5 (D) x 7 in (H)48.26 cm (W) x 34.29 cm (D) x 17.78 cm (H)
Weight
11 lbs/5 kg

Electrical Specifications

All parameters are specified at 25°C in the vertical position unless
otherwise stated.
GS-ONE
GS-ONE LF
Response Frequency
10 Hz, ± 0.35 Hz
5 Hz, ± 0.5 Hz
Spurious frequency
240 Hz Typical
160 Hz Typical
Distortion at Vertical*
0.05% Typical
<0.10% Typical
Sensitivity with 20 kΩ load
2.00 V/in/s (78.7 V/m/s) Typical
2.27 V/in/s (89.4 V/m/s) Typical
Damping with 20 kΩ load
0.70 Typical
0.670 Typical
DC resistance
1800 Ω, ± 5%
2450 Ω, ± 5%
*Distortion Measured @ 12 Hz with 0.7 in/s Pk-Pk Velocity

 

Digitization
24-Bit Delta-Sigma
Sample Rate
0.5, 1, 2, 4 ms
Preamplifier Gains
0, 6, 12, 18, 24, 30, 36 dB
Maximum Input Signal for Sensor
26 mm/sec
Equivalent Input Noise
@ 2 ms sample rate 1.77 μmm/sec rms
Gain Accuracy
Better than 1%
Anti-alias Filter
83% Nyquist
Instantaneous Dynamic Range
124 dB @ 2 ms sample interval
Crossfeed Isolation
>90 dB
THD
<0.2%