PRODUCT DETAILS
The GS-ONE LF 4.5Hz & 5Hz geophones’ improved sensitivity makes these single-element vibration monitoring systems’ designs compatible with the latest 24-bit data acquisition systems’ capabilities to record the extended dynamic range and bandwidth.
Features
- Moving mass: 25.2g (0.889 ounces)
- Maximum coil excursion p-p: Less than 3mm (0.120 inches)
- Diameter is 30.5 mm (1.2 inches)
- Height less terminals is 40.7 mm (1.6 inches)
- Weight is 131.00g (4.60 ounces)
- Operation and Storage Temperature Range -40 to 80°C (-40 to 176°F)
SPECIFICATIONS (5 HZ)
Vertical MECHANICAL SPECIFICATIONS
Moving mass
|
25.2 g
|
0.889 oz
|
Maximum coil excursion p-p
|
3.05 mm
|
0.120 in.
|
Diameter
|
30.5 mm
|
1.2 in.
|
Height
|
40.6 mm
|
1.6 in.
|
Weight
|
131 g
|
4.62 oz
|
Operating and storage temperature range
|
–40°C to +80°C
|
–40°F to +176°F
|
Electrical Specifications
All parameters are specified at 25°C in the vertical position unless otherwise stated.
Open-circuit sensitivity
|
2.55 V/in/s (100.4 V/m/s) +10%, –10%
|
Frequency
|
4.5 Hz ±0.75 Hz
|
Spurious frequency
|
120 Hz typical
|
Distortion at vertical
|
0.25% Typical measured at 12 Hz with 0.7 in/s p-p
|
Open-circuit damping
|
0.42 ±0.10
|
Coil resistance
|
2450 Ω ±5%
|
Sensitivity with 20 kΩ load
|
2.27 V/in/s (89.4 V/m/s) typical
|
Damping with 20 kΩ load
|
0.735 typical
|
Tilt angle when coil hits end stop
|
24° from vertical Typical
|
Horizontal MECHANICAL SPECIFICATIONS
Moving mass
|
25.2 g
|
0.889 oz
|
Maximum coil excursion p-p
|
3.05 mm
|
0.120 in.
|
Diameter
|
30.5 mm
|
1.2 in.
|
Height
|
40.6 mm
|
1.6 in.
|
Weight
|
131 g
|
4.62 oz
|
Operating and storage temperature range
|
–40°C to +80°C
|
–40°F to +176°F
|
Electrical Specifications
All parameters are specified at 25°C in the horizontal position unless otherwise stated.
Open-circuit sensitivity
|
2.55 V/in/s (100.4 V/m/s) +10%, –10%
|
Frequency
|
4.5 Hz ±0.75 Hz
|
Spurious frequency
|
120 Hz typical
|
Distortion at horizontal
|
0.25% Typical measured at 12 Hz with 0.7 in/s p-p
|
Open-circuit damping
|
0.42 ± 0.10
|
Coil resistance
|
2450 Ω ±5%
|
Sensitivity with 20 kΩ load
|
2.27 V/in/s (89.4 V/m/s) typical
|
Damping with 20 kΩ load
|
0.735 typical
|
Tilt angle when coil hits end stop
|
5° from horizontal
|
SPECIFICATIONS (4.5 HZ)
Vertical MECHANICAL SPECIFICATIONS
Moving mass
|
25.2 g
|
0.889 oz
|
Maximum coil excursion p-p
|
3.05 mm
|
0.120 in.
|
Diameter
|
30.5 mm
|
1.2 in.
|
Height
|
40.6 mm
|
1.6 in.
|
Weight
|
131 g
|
4.62 oz
|
Operating and storage temperature range
|
–40°C to +80°C
|
–40°F to +176°F
|
Electrical Specifications
Open-circuit sensitivity
|
2.55 V/in/s (100.4 V/m/s) +10%, –10%
|
Frequency
|
4.5 Hz ±0.75 Hz
|
Spurious frequency
|
120 Hz typical
|
Distortion at vertical
|
0.25% typical measured at 12 Hz with 0.7 in/s p-p
|
Open-circuit damping
|
0.42 ±0.10
|
Sensitivity with 20 kΩ load
|
2.27 V/in/s (89.4 V/m/s) typical
|
Damping with 20 kΩ load
|
0.735 typical
|
Tilt angle when coil hits end stop
|
24° from vertical typical
|
Horizontal MECHANICAL SPECIFICATIONS
All parameters are specified at 25°C in the horizontal position unless otherwise stated.
Open-circuit sensitivity
|
2.55 V/in/s (100.4 V/m/s) +10%, –10%
|
|
Frequency
|
4.5 Hz ±0.75 Hz
|
|
Spurious frequency
|
120 Hz typical
|
|
Distortion at horizontal
|
0.25% typical measured at 12 Hz with 0.7 in/s p-p
|
|
Open-circuit damping
|
0.42 ±0.10
|
|
Coil resistance
|
2450 Ω ±5%
|
|
Sensitivity with 20 kΩ load
|
2.27 V/in/s (89.4 V/m/s) typical
|
|
Damping with 20 kΩ load
|
0.735 typical
|
|
Tilt angle when coil hit end stop
|
5° typical from horizontal
|
Electrical Specifications
All parameters are specified at 25°C in the horizontal position unless otherwise stated.
Open-circuit sensitivity
|
2.55 V/in/s (100.4 V/m/s) +10%, –10%
|
Frequency
|
4.5 Hz ±0.75 Hz
|
Spurious frequency
|
120 Hz typical
|
Distortion at horizontal
|
0.25% typical measured at 12 Hz with 0.7 in/s p-p
|
Open-circuit damping
|
0.42 ±0.10
|
Coil resistance
|
2450 Ω ±5%
|
Sensitivity with 20 kΩ load
|
2.27 V/in/s (89.4 V/m/s) typical
|
Damping with 20 kΩ load
|
0.735 typical
|
Tilt angle when coil hit end stop
|
5° typical from horizontal
|