DW-150
DW-150 “Slimhole Array System”

PRODUCT DETAILS
Miniaturized Multi-Component Borehole Sonde String
The DW-150 is a miniaturized, multi-component borehole sonde string utilizing an ultra low-noise digitizer, which enables the recording of low-amplitude microseismic events, 3D-VSP, and crosswell seismic imaging.
Features
- 24-bit x three-channel digitizer in each shuttle
- Ultra low-noise digitizer enables recording of low-amplitude microseismic events, 3D-VSP, Crosswell Seismic Imaging, etc
- Slim-hole sonde 1.6 inch OD (<41 mm)
- 3C sensor packages available: 3C tri-axis orthogonal Geophone
- OMNI-2400 high-output Geophone sensors
- Machined stainless housing minimizes mechanical resonance for high-resolution, high-frequency recording
- Direct connection sub-arrays, armored wireline, or rigid interconnects available with high-pressure multi-conductor booted connectors
- Flexible or rigid interconnects may be connected “back-to-back” to form longer intervals
- Maximum distance between sonde modules: 100 meters
- Maximum temperature rating: 150°C
- Maximum pressure rating: 20,000 psi
- Configurations for vertical, deviated, or horizontal wellbore deployments
- Adaptable housing for user-defined, application-specific coupling devices
Mechanical Specifications
Outside Diameter
|
1.6 inches
|
< 40.64 mm
|
Length
|
16 inches
|
406.4 mm
|
Tool Weight
|
5 lbs.
|
2.27 kg
|
Anchoring System
|
Mechanical on each shuttle (bow spring/magnetic)
|
Tubing mandrel Permanent (cemented)
|
Anchor-to-Weight ratio
|
7:1 (passive spring)
|
|
Tool Anchoring Range
|
Custom adapters for dimension ranges
|
Sizes available upon request
|
Points of Contact
|
5 points, including oposing clamp axis
|
|
Sensor Package
|
3C w/OMNI-2400, mutually orthogonal sensor set standard 2.26
Volts/inch/second Sensitivity |
|
Interconnect Options
|
Rigid Tubing
|
Flexible Armored Wireline Cable
|
Standard Lengths
|
3, 6, 9, 9, 12, 15, 20 meters
|
|
Maximum Temperature
|
302°F
|
150°C
|
Maximum Pressure
|
20,000 psi
|
DIGITAL MODULE 3-CH X 24-BIT DIGITIZER SPECIFICATIONS
Sampling Rates
|
¼, ½, 1, 2, and 4 ms
|
Pre-amplifier Gains
|
0dB, 6 dB, 12 dB, 18 dB, 24 dB, 30 dB, 36 dB
|
Equivalent Input Noise @2 MS
|
1.13μV rms, 0.58 μV rms, 0.33 μV rms, 0.22 μV rms, 0.19 μV rms, 0.18 μV rms, 0.17 μV rms
|
Maximum Input Signal
|
1.8 V rms, 0.9 Vrms, 0.45 Vrms, 0.225 Vrms, 0.1125 Vrms, 0.0562 Vrms, 0.0281Vrms
|
Gain Accuracy
|
< 1%
|
Frequency Response
|
3 to 1.65 KHz
|
Anti-alias Filter
|
83% Nyquist
|
Instant. Dynamic Range @2 MS
|
124 dB
|
Cross-feed Isolation
|
>90 dB
|
THD
|
0.001%
|
System Timing Accuracy
|
Better than 1 PPM
|